AUXILIARY ALTERNATOR CONTROL PANEL
POWER CIRCUIT BREAKER CLOSE LIGHT (Red)
This light indicated when the main power control breaker is closed.
POWER BREAKER OPEN BUTTON and POWER BREAKER CLOSED BUTTON
These push buttons are used for remote operation of the main power control breaker which is located in the control compartment. The breaker is motor-operated with a manual override.
GENERATOR EXCITATION START BUTTON and GENERATOR EXCITATION STOP BUTTON
These push buttons control the application of excitation for the appropriate auxiliary power supply alternator to the power control breaker.
AUXILIARY POWER CONTROL BREAKER
This breaker controls opening and closing of the Main Power Control Breaker and functions of the Auxiliary Power Excitation Control.
PHASE AMP SELECTOR SWITCH
This switch is used for reading current in any one of the three phases of auxiliary power.
VOLTMETER TRANSFER SWITCH
This switch is used to read the voltage between any of the three phases of auxiliary power.